
Operations Guide 930796L CyberData Corporation
Installing the VoIP Outdoor Intercom
Intercom Setup
9
2.3.2 Using the On-Board Relay
Warning
Electrical Hazard:
Warning
Electrical Hazard:
Warning
Electrical Hazard:
The device has a built-in relay that can be activated by a web configurable DTMF string that can be
received from a VoIP phone supporting out of band (RFC2833) DTMF as well as a number of other
triggering events. See the Device Configuration Page on the web interface for relay settings.
This relay can be used to trigger low current devices like strobes and security camera input signals
a
s long as the load is not an inductive type and the relay is limited to a maximum of
1 Amp @ 30 VDC. Inductive loads have caused excessive “hum” and can interfere with the unit’s
e
lectronics.
We highly recommend that inductive load and high current
devices use our Door Strike Intermediate
Relay product (CD# 011269) (see Section 2.3.3.2, "Connecting the Door Strike Intermediate Relay
Module").
This relay interface also has a general purpose input port that can be used to monitor an external
s
witch and generate an event.
For more information on the sensor options, see the Sensor Configuration Page on the web
interface.
This product should be installed by a licensed electrician
according to all local electrical and building codes.
The relay contacts are dry and provided for a normally open
and momentarily closed configuration. Neither the alternate power input nor PoE
power can be used to drive a door strike.
The relay does not support AC powered door strikes.
Any use of this relay beyond its normal operating range can cause damage to the
product and is not covered under our warranty policy.
Kommentare zu diesen Handbüchern