Installing the VoIP Emergency Intercom
Configure the SIP Parameters
Operations Guide 930279W CyberData Corporation
36
2. On the SIP Configuration page, enter values for the parameters indicated in Table 2-9.
Table 2-9. SIP Configuration Parameters
Web Page Item Description
Enable SIP Operation Enables or disables SIP operation.
SIP Settings
Type the SIP server represented as either a numeric IP
address in dotted decimal notation or the fully qualified
host name (255 character limit [FQDN]).
SIP Server Use this field to set the address (in dotted decimal notation
or as a canonical name) of the SIP registrar. This field can
accept canonical names of up to 255 characters in length.
Backup SIP Server 1
Backup SIP Server 2
When the primary SIP Server goes offline and the device
fails to register after the normal re-registration interval, the
controller will fall back to using Backup SIP Server 1.
If Backup SIP Server 1 fails, the device will use Backup SIP
Server 2.
If a higher priority SIP Server comes back online, the
device will switch back to this server.
You can leave the Backup SIP Server 1 and Backup SIP
Server 2 fields blank.
Remote SIP Port* Type the Remote SIP Port number (default 5060)
(8 character limit).
Local SIP Port* Type the Local SIP Port number (default 5060)
(8 character limit).
Outbound Proxy Type the Outbound Proxy as either a numeric IP address in
dotted decimal notation or the fully qualified host name
(255 character limit [FQDN]).
Outbound Proxy Port Type the Outbound Proxy Port number (8 character limit).
SIP User ID* Type the SIP User ID (up to 64 alphanumeric characters).
Authenticate ID* Type the Authenticate ID
(up to 64 alphanumeric characters).
Authenticate Password* Type the Authenticate Password (up to 64 alphanumeric
characters).
Register with a SIP Server* Check this box to enable SIP Registration.
For information about Point-to-Point Configuration, see
Section 2.3.5.2, "Point-to-Point Configuration".
Re-registration Interval (in seconds)* Type the SIP Registration lease time in minutes (default is
60 minutes) (8 character limit). Re-registration Interval (in
seconds)*
Unregister on Reboot* When selected, on boot, the device will first register with a
SIP server with a expiration delay of 0 seconds. This has
the effect of unregistering any current devices on this
extension.